KS-Efficient Series Online UPS (1:1 Phase)

 

Application:
Small IT network, Services and other IT equirpment
Features:
1. High frequency and double conversion online technology
2. Fully digitized microprocessor control
3. Wide input voltage range
4. LCD display
5.  UPS start up without battery
6. Cold start
7. Advanced battery management
8. Lightning and surge protection
9. Shot circuit and overload protection
10. Network/fax/modem surge kprotection
11. Smart RS232 communication with monitoring software
12. Optional SNMP card slot
MODELS EFSS1K24L EFSS1K36L EFSS2K48L EFSS2K96L EFSS3K72L EFSS3K96L EFSS6K240L EFSS10K240L
CAPACITY 1KVA/700W 2KVA/1400W 3KVA/2100W 6KVA/4.2KW 10KVA/7kW
INPUT
Voltage Range When load<60%. input range is 115±5VAC-295±5VAC 176V-276VAC±5V
When load>60%,   input range is 160±5VAC-295±5VAC
Frequency Range 50Hz±5Hz
Phase Single phase
Power Factor >0.97 >0.98
OUTPUT
Voltage Range 220/230Vac±2%
Frequency Range Sychronized with the utility on AC mode; 50Hz±0.2% on Battery mode    
THD (linear load) <3% <2%
THD (non-linear load) <6%
Overload Capability >110%, 30s turn to bypass mode:>150%, 200ms turn to bypass mode
Crest Factor 3:1 (max)
Short Circuit Protection 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode) 5 cycles turn off inverter, provide alarm (battery mode) input fuse blown or breaker action (bypass mode)
Waveform Pure Sine Wave
Transfer Time Between AC Mode and Battery Mode : 0ms
Between AC Mode and Bypass Mode 4ms (typical value 2.5ms)
Efficiency >83% >85% >88%
BATTERY
Model 1 2V sealed lead acid maintenance free
DC Voltage 24VDC 36VDC 48VDC 96VDC 72VDC 96VDC 240VDC
Charging Technology SMPS Based
Charge Current 7A 5A
Recharge Time 90% capacity after 8hrs charging
INDICATION & COMMUNICATION
Communication Interface RS232 ; SNMP (optional)
LCD 1. Input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA and percent, inverter temperature
2. Operation mode such as "on line", "on batt", or "or bypass"
LED 1. Green LED for normal operation,
2. Yellow LED for warning condition
3. Red LED for abnormal operation
ENVIRONMENT
Noise Level <55dB
Temperature 0~40`C
Humidity 0%~95% (non-condensing)
Altitude <1500m
Storage Temperature 25~55'C
MECHNICALS
Standard Unit Net/Gross Weight 8/10Kg 8/10Kg 14/16Kg 14/16Kg 15/17Kg 15/17Kg 34/48Kg 36/51Kg
Dimension (WxDxH)mm 144×419×215 144×419×215 191×478×339 191×478×339 191x478x339 191x478x339 270×570×720 270×570×720
Packing (WxDxH)mm 258×524×334 258×524×334 332×603×482 332×603×482 332x603x482 332x603x482 370×670×940 370×670×940
 
     

 

 

 